Technical Resources
How to Prepare Data for Coupling Selection
A practical checklist for sending torque, speed, shaft, displacement and installation information.
Answer first
A useful coupling inquiry begins with the actual duty and both shaft interfaces. A model name alone is rarely enough for a safe preliminary review.
Minimum operating data
Driving and driven equipment
Power, normal speed and maximum speed
Nominal, peak and starting torque where available
Start-stop frequency, reversing, shock and braking conditions
Radial, axial and angular displacement
Connection and space data
Shaft diameters at both ends
Shaft-extension and bore lengths
Bore and keyway forms
Maximum outside diameter and overall length
Maintenance and dismantling clearance
Additional data for cardan shafts
State the installed length, required telescopic movement, operating angle, swing-diameter clearance, flange pilot and bolt-hole dimensions, phasing requirements, nominal torque and fatigue torque.
Boundary
Preliminary family screening does not replace final engineering confirmation. Current standards, material, balancing, heat treatment, service life and contractual performance must be confirmed for the selected product and duty.